<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>66block.net</title>
	<atom:link href="http://66block.net/feed/" rel="self" type="application/rss+xml" />
	<link>http://66block.net</link>
	<description></description>
	<lastBuildDate>Tue, 15 Nov 2011 04:13:49 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.2.1</generator>
<xhtml:meta xmlns:xhtml="http://www.w3.org/1999/xhtml" name="robots" content="noindex" />
		<item>
		<title>110 Blocks</title>
		<link>http://66block.net/using-110-blocks/110-blocks/</link>
		<comments>http://66block.net/using-110-blocks/110-blocks/#comments</comments>
		<pubDate>Wed, 12 Oct 2011 02:27:57 +0000</pubDate>
		<dc:creator>fbbadmin</dc:creator>
				<category><![CDATA[Using 110 Blocks]]></category>

		<guid isPermaLink="false">http://66block.net/?p=21</guid>
		<description><![CDATA[Using 110 Blocks? Are you currently utilizing a 110 block for phone cabling or information network wiring? Whether you are  it yourself or perhaps a specialized installation technician utilizing a 110 block for network wiring can be achieved simply for those who understand the basic principles. A 110 block the type of  punch down block &#8230; <a href="http://66block.net/using-110-blocks/110-blocks/">Continue reading</a>]]></description>
			<content:encoded><![CDATA[<h1>Using 110 Blocks?</h1>
<div id="attachment_22" class="wp-caption alignright" style="width: 310px"><a href="http://66block.net/wp-content/uploads/2011/10/800px-110-punch-block-IDC-0a.jpg"><img class="size-medium wp-image-22" title="110 Block" src="http://66block.net/wp-content/uploads/2011/10/800px-110-punch-block-IDC-0a-300x225.jpg" alt="110 Block" width="300" height="225" /></a><p class="wp-caption-text">110 Block</p></div>
<p>Are you currently utilizing a <strong>110 block</strong> for phone cabling or information network wiring? Whether you are  it yourself or perhaps a specialized installation technician utilizing a 110 block for network wiring can be achieved simply for those who understand the basic principles. A 110 block the type of  punch down block which is used for voice and data inside a network wiring system. In the past phone systems utilized screw terminals to connect wires which had to be linked for supporting phone services. After a while these screw terminals have been supplanted through the creation of a 110 block along with a 66 block. A 110 block is essentially a distribution panel for on site cabling. It makes it simple to arrange and disperse telecom and information services over to the customers. Inside a home application this might signify using the voice and information services from an entrance area over to every room that will have network solutions readily available. In an enterprise environment this could mean utilizing the voice and data services from your primary access point over to each and every cubical or area which may also have telephone services or possibly a laptop or computer. These network solutions could be both data or phone services. From your 110 block phone cable or network wire is going to be ran to every area and terminated within an outlet or keystone jack port. This jack allows you to merely connect a telephone or personal computer into the network system.</p>
<h2>Installing A 110 Block</h2>
<p>A <span style="text-decoration: underline;">110 block</span> is generally installed on a back panel or right on the wall which enables you to simply deliver the cables in for fresh terminations. To terminate wires on top of a 110 block you will have to utilize a punch down tool which has a 110 format blade on it. This cutter combined with the punch down motion pushes the cable to install to the 110 block whilst the tool cuts extra cable leftover from the termination. This punch down motion results in a powerful link between the 110 block as well as the network wire. In summary a very structured distribution panel that&#8217;s set up to assist your voice and information system connections. There are actually 110 block solutions to assist either Cat 6 and Cat5e network purposes. Also, you can find 110 blocks on the market to assistance small, medium, and large network installs.  When selecting the <em>110 block</em> choice that matches your network installation it is very important to guarantee the solutions you utilize adhere to TIA/EIA 568-B.2-1 specifications. Ensure that the solutions you select are manufactured by trustworthy companies which are know within the wires industry. Consider the specs of the products and ensure it&#8217;s got the options and ratings to compliment your application. These items are comparatively cheap so it doesn&#8217;t appear sensible to accept the danger and employ substandard solutions. Your network is only going to perform as quickly as its weakest link. Don&#8217;t permit low quality 110 block solutions and components help make your network under-perform. Pick the wires items that are trustworthy!</p>
]]></content:encoded>
			<wfw:commentRss>http://66block.net/using-110-blocks/110-blocks/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Punch Down Blocks</title>
		<link>http://66block.net/punch-down-blocks/punch-down-blocks/</link>
		<comments>http://66block.net/punch-down-blocks/punch-down-blocks/#comments</comments>
		<pubDate>Tue, 11 Oct 2011 02:59:40 +0000</pubDate>
		<dc:creator>fbbadmin</dc:creator>
				<category><![CDATA[Punch Down Blocks]]></category>

		<guid isPermaLink="false">http://66block.net/?p=12</guid>
		<description><![CDATA[What Are Punch Down Blocks Punch-down blocks have been designed to supply a interconnection point for telephone cables. They streamline cabling installment by giving an individual termination position for wires coming into a building or cabling cabinet. Every strand of twisted pair wire is semipermanently hard pressed in to a channel within the punch-down block. &#8230; <a href="http://66block.net/punch-down-blocks/punch-down-blocks/">Continue reading</a>]]></description>
			<content:encoded><![CDATA[<h1>What Are Punch Down Blocks</h1>
<p>Punch-down blocks have been designed to supply a interconnection point for telephone cables. They streamline cabling installment by giving an individual termination position for wires coming into a building or cabling cabinet. Every strand of twisted pair wire is semipermanently hard pressed in to a channel within the punch-down block. The channel anchors the strand and permeates the insulating material to supply the electrical interconnection.</p>
<p>There are many kinds of <strong>punch down block</strong>s from different suppliers; two of the most typical are:</p>
<p>Siemens S66M1-50 termination block, frequently known as a &#8220;66 block&#8221;</p>
<p>AT&amp;T 110/A Block, generally referred to as a &#8220;110 block&#8221;<br />
From the <span style="text-decoration: underline;">punch down block</span>, patch wires can eventually be run to the jacks of equipment, like hubs (for LAN cabling) or perhaps a private branch exchange (PBX) (for voice cables).</p>
<p>The 66 Block Diagram exhibits how connections are set up on the <em>punch down block</em>. In each and every horizontally strip, the 2 left hand contacts use a built in power link between them. Similarly, the 2 right hand connections also share a built in link. The middle 2 connections aren&#8217;t immediately linked to one another, but could be connected by punching a cable on to each connections, or linking these with metallic &#8220;bridging clip.&#8221; Once the 2 middle connections within the exact same row are linked, the many other connections on a single row are electronically linked to one another.</p>
<h2>66 Block Diagram<span class="Apple-style-span" style="font-size: 13px; font-weight: normal;"> </span></h2>
<div id="attachment_13" class="wp-caption alignleft" style="width: 310px"><a href="http://66block.net/wp-content/uploads/2011/10/66Block.gif"><img class="size-medium wp-image-13" title="66 Block Diagram" src="http://66block.net/wp-content/uploads/2011/10/66Block-300x253.gif" alt="66 Block Diagram" width="300" height="253" /></a><p class="wp-caption-text">66 Block Diagram</p></div>
<p>The 66 Block Diagram displays how a punch-down block is generally utilized to link client owned or operated LAN cabling to the wires possessed by the phone company. Every single inbound telecom company cable is linked to 1 of the exterior connections on the 66 block. To carry on that interconnection in to the LAN, the client joins an additional cable, such as one follicle of a Category 5 cable, to the complete opposite exterior connection on the exact same row. Then the client links the 2 middle connections to connect the phone company line to the LAN cable. This technique of linking wires is less dangerous and much more structured than merely folding the ends of 2 cables together.<br />
A 66 block consists of fifty rows of connections. This is sufficient to terminate an arriving 25-pair wire on 1 section, and link each and every cable of that set to a matching cable on the other section of the block.<br />
In most instances, a network specialist might terminate a 50 pair wire on a solitary 66 block, by making use of every exterior set of connections to link 1 inbound cable and 1 LAN cable. The two middle connections are not linked, so the complete opposite set of connections on the exact same row will be utilized to link a distinct exterior cable to a different interior cable. This layout is refered to as a &#8220;split 66 block,&#8221; due to the fact the block is successfully divided in to when the middle set of connections is not linked.<br />
Punch-down blocks are generally installed to plyboard sections fastened to the cabling cabinet walls. Some punch-down blocks can come with a sequence of RJ-45 outlets, so that specific cables can be punched down at one area, and connectorized patch wires can be connected at the other.</p>
]]></content:encoded>
			<wfw:commentRss>http://66block.net/punch-down-blocks/punch-down-blocks/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>66 Block</title>
		<link>http://66block.net/what-is-a-66-block/66-block/</link>
		<comments>http://66block.net/what-is-a-66-block/66-block/#comments</comments>
		<pubDate>Mon, 10 Oct 2011 13:18:12 +0000</pubDate>
		<dc:creator>fbbadmin</dc:creator>
				<category><![CDATA[What is a 66 Block]]></category>
		<category><![CDATA[66 Block]]></category>

		<guid isPermaLink="false">http://66block.net/?p=1</guid>
		<description><![CDATA[What is a 66 Block? 66 Blocks likewise known as M-Blocks are a style of punchdown block utilised to link units of cables throughout a telephone system. 66 blocks are generally intended to terminate 22 thru 26 AWG solid copper wire. The 25-pair traditional non-split 66 Block contains 50 rows; each row has four columns &#8230; <a href="http://66block.net/what-is-a-66-block/66-block/">Continue reading</a>]]></description>
			<content:encoded><![CDATA[<h1>What is a 66 Block?</h1>
<div id="attachment_9" class="wp-caption alignright" style="width: 197px"><a href="http://66block.net/wp-content/uploads/2011/10/375px-66_block.jpg"><img class="size-medium wp-image-9" title="66 block" src="http://66block.net/wp-content/uploads/2011/10/375px-66_block-187x300.jpg" alt="66 block" width="187" height="300" /></a><p class="wp-caption-text">66 Block Image</p></div>
<p>66 Blocks likewise known as M-Blocks are a style of punchdown block utilised to link units of cables throughout a telephone system. 66 blocks are generally intended to terminate 22 thru 26 AWG solid copper wire.</p>
<p>The 25-pair traditional non-split <strong>66 Block</strong> contains 50 rows; each row has four columns of clips which are electrically bonded.<br />
The 25-pair &#8220;Split 50&#8243; <span style="text-decoration: underline;">66 Block</span> is the industry standard for quick termination associated with voice cabling, and is the typical network termination by telephone companies-generally for professional premises. Each and every row includes several clips, however , the left two clips are electrically separated from the right two clips.<br />
66 blocks pre-assembled with an RJ-21 female connector happen to be available that will allow a quick link to a 25-pair cable with a male end. Most of these connections are typically made between the actual block and the CPE (customer premise equipment).</p>
<h2>66 Block Uses</h2>
<p>Circuit pairs are connected to the block utilizing a punch-down instrument simply by terminating the tip cable upon the leftmost slot of 1 row and ring cable upon the leftmost slot of the row down below the mating tip cable. Typically, a 25-pair wire coming via the phone company is punched down upon the left edge of the block in pairs. The right hand edge of the block is wired to the customer premise equipment (CPE) with jumper cables. Bridging clips will be applied to hook up the two middle terminals, joining the left-hand section of the split block with it&#8217;s right-hand section, hence completing the circuit. The clips form the point of interface in between the subscriber along with the provider. The bridging clips may be very easily taken out by either the subscriber or phone company staff members for issues isolation, enabling the capability to split a circuit and figure out in which route trouble might exist. An orange insulating cover connected to a <em>66 block</em> means it&#8217;s status as a demarcation point by the neighborhood exchange provider.</p>
<h3>Decline of 66 Blocks</h3>
<p>At present, 66 blocks tend to be deemed legacy devices. In comparison to more modern day cable terminating devices they are physically large, and simply because of their maximum 16 Megahertz Category three signaling compatibility, they tend to be ill fitted for high speed data circuits quicker than 10BASE-T. However, right now there are unique Cat5e Certified 66 blocks available from producers such as Siemon which usually fulfill all specifications for Cat5e termination.<br />
&#8216;Split 50&#8242; 66 blocks are still utilized as network interface blocks in distribution frames to interconnect circuits with connecting clips, but are mainly restricted to narrowband circuits such because POTS/DSL, DS0, or DS1 circuits.<br />
Current 110 blocks currently have largely supplanted 66 blocks within brand new installations simply because the newer termination is almost usually Category 5 compliant, and capable of assisting one hundred Megahertz or even quicker signaling.</p>